Time relays with switch off delay switch on the consumer after the specified delay time has elapsed. Please specify the desired delay time when ordering. All schematics: Operating voltage is applied to terminal 30/87z. If the voltage is applied to terminal 15, the relay will immediately pull on. If the voltage is removed at Terminal 15, the relay will fall off after the specified time has elapsed.
Circuit diagram S2: The contacts are separate from the control and can therefore be used in links. In this variant, the relay contact is completely potential-free and thus capable of switching alternating voltage. Circuit diagram S4: The relay does not consume a quiescent current by the diode circuitry after the drop. Variant S4 only 10/15a (ö/s). Housing forms can be found in the section housing and basic body.
Additional information
Inputs & Outputs
Number of pins: 5 Inputs (total): 1 Inputs (digital): 1 In-/Outputs (total): 2 Outputs (total): 1 Relay outputs: 1 Switching current: NO 20 A / NC 15 A
Programming
Programming software: MRS Realizer
Mechanical properties
IP rating: up to IP6K8 Housing material: PA66GF30 Dimensions: 30 × 30 × 40 mm Switching cycles: 100000
General information
Temperature range: -40 to +85°C Operating voltage: 9-16 V Current consumption: 2 ± 1 mAÂ